Flow Cytometry Core Laboratory

Instrumentation

LSR II

Photo of LSR II

Description

This instrument is equipped with three diode pumped solid-state lasers (Blue-488nm, Green-534nm, Violet-408nm and a Red-633nm). The Green (Coherent-Compass) laser is unique and has a total laser output of 150mW, while all other lasers are low energy 25mW lasers. As shown at top of figure 7 (Figure 7. Laser Path and Octagon of the LSR II) (PDF), each laser line can be independently adjusted through a series of steering mirrors. The lasers are set in the following delay timing order, blue, violet, red and green with the blue laser as the reference laser. The bottom right shows the octagon assembly for detection of the green laser-excited emissions. This unique collection system is composed of a series of photomultiplier tubes (PMT's) and optics in an octagonal arrangement. Photons enter this system and are systematically reflected to the next detector by a dichroic mirror or transmitted through a band pass filter and counted in that PMT. Each detector quantifies light principally, but not solely, from a single fluorochrome.

Figure 7. Laser Path and Octagon of the LSR

Figure 7. Laser Path and Octagon of the LSR

The geometry of this instrument is based on recent advances in light optics and far-red sensitive collection detectors (PMT). These instruments use optical fibers to transmit photons of light from the laser-excited conjugates are transmitted through optical fibers and measured in unique optical arrays. The flexibility of these systems allow for the current design with 18 fluorescent detectors and two physical parameters. This current optical design (Figure 8. Filter Configuration) (PDF), shows the dichroic mirrors and band-pass filter arrangement. This configuration allows for 2 fluorescent detectors dedicated to blue laser excitation, 5 fluorescent detectors dedicated to green laser excitation, 8 fluorescent detectors dedicated to violet laser excitation and 3 fluorescent detectors dedicated to red laser excitation. Note the configuration nomenclature for the detectors is listed in table 2 below. This uses the excitation laser (G=green laser, B=blue laser, R=red laser and V=violet laser) and the peak detection location (660nm for the APC channel) as the detector name (e.g. APC detection would be measured in R660).

Diagram of Green DPSS Laser 532nm Octagon

Figure 8. Filter Configuration

Diagram of Violet DPSS Laser 407nm Octagon

Figure 8. Filter Configuration

Figure 8. Filter Configuration

Table 2. Detector Configuration and Nomenclature


 Table 2. Detector Configuration and Nomenclature

back to top

Photo of Mario Roederer, Ph.D.

Contact Info

Mario Roederer, Ph.D., Director
Phone: 301-594-8491
Fax: 301-480-2788
E-mail: Roederer@nih.gov

Stephen Perfetto, Manager
Phone:301-594-8659
Fax: 301-480-2788
E-mail:Sperfetto@nih.gov

Richard Nguyen, Specialist
E-mail: rnguyen@nih.gov

David Ambrozak, Specialist
E-mail:dambrozak@nih.gov

Mail:
NIH
Vaccine Research Center
40 Convent Drive
Bldg. 40, Room 5508
Bethesda, MD, 20892-3015

See Also

  • Vaccine Research Center
  • VRC Research Areas

  • NIH Logo

    The National Institute of Allergy and Infectious Diseases is a component of the National Institutes of Health, U.S. Department of Health and Human Services

    NIAID Logo

    Search in Labs at NIAID
     
    Print Icon Print this page
    E-mail Icon E-mail this page
    Plug-ins and Viewers
    To open PDFs on this page, download and install the Adobe Acrobat Reader.
    Photo of Mario Roederer, Ph.D.

    Contact Info

    Mario Roederer, Ph.D., Director
    Phone: 301-594-8491
    Fax: 301-480-2788
    E-mail: Roederer@nih.gov

    Stephen Perfetto, Manager
    Phone:301-594-8659
    Fax: 301-480-2788
    E-mail:Sperfetto@nih.gov

    Richard Nguyen, Specialist
    E-mail: rnguyen@nih.gov

    David Ambrozak, Specialist
    E-mail:dambrozak@nih.gov

    Mail:
    NIH
    Vaccine Research Center
    40 Convent Drive
    Bldg. 40, Room 5508
    Bethesda, MD, 20892-3015

    See Also

  • Vaccine Research Center
  • VRC Research Areas