National Institute of Allergy and Infectious Diseases
  National Institutes of Health
NIAID Home Health & Science Research Funding Research News & Events Labs at NIAID About NIAID

Labs at NIAID
 Info about NIAID Labs
  Comparative Medicine
  Cytokine Biology
  LAD
  LCID
  LCMI
  LHD
  LHBP
  LIG
  LI
  LIP
  LID
  LIR
  LICP
  MVDB
  LMVR
  LMI
  LMM
  LPD
  LPVD
  LV
  LVD
  LZP
  PSIIM
  Research Technologies
  Vaccine Research Center
   Biodefense Research
   BSL-3 Core Virology
   Cellular Immunology Laboratory
   Clinical Trials Core
   Flow Cytometry Core
   Human Immunology
   Immunology
   Immunology Core
   Immuno Technology
   Laboratory Animal Medicine
   Structural Biology
   Structural Virology Laboratory
   Vaccine Production
   Vaccine Product Development Laboratory
   Viral Pathogenesis
   Virology and Vector Core
 Find Key Lab Scientists
 Training in NIAID Labs


Vaccine Research Center

Flow Cytometry Core Laboratory

General Procedures

Quality Control Procedures

Instrumentation Quality Control

Quality control issues are of concern because of the likelihood that flow cytometric data are used to make clinical decisions, especially with respect to the medical management of human immunodeficiency virus type 1 (HIV-1) infected patients. A good quality control program is designed to assess the major instrument parameters that affect the reliability and reproducibility of data. After installation, certain components of the instrument should be tested for minimal performance. In addition, certain parameters require routine evaluation to ensure the proper functioning of the system. The efficiency and performance of optical filters, linear amplifiers, and the PMT responses should be examined. Once a reliable level of performance is established, many instrument problems can be avoided by adherence to the manufacturer's recommended maintenance schedules.

A well-designed monitoring procedure should identify both immediate and potential problems. Results of daily monitoring of instrument performance should be kept in computer logs so that trends and variations can be noted. In addition, the corrective action database is used to track and search daily problems and solutions as well as tracking service calls. For each parameter measured, tolerance limits should be established which define the acceptable range of performance. It is recommended that Levy-Jennings style charts should be used to visually inspect longitudinal data for monitoring instrument performance for precision and trends. Initial limits are derived mathematically with as few as 20 separate data points. Tolerance ranges for each parameter are defined as two standard deviations above and below the geometric mean. New ranges can be calculated periodically from the cumulative database. Tolerance limits are established for daily monitoring of optical alignment, calibration of the fluorescent intensity standard curve, and bi-weekly monitoring of electronic fluorescent compensation.

Three levels of quality control are monitored and maintained to provide an accurate determination of instrument quality assurance. These are alignment, calibration and standardization. Alignment refers to the use of latex beads (1x Rainbow beads) for optically focusing the laser and for the measurement of laser power. Calibration refers to the use of latex particles used for laser delay setting calibration (1x Rainbow beads). Standardization refers to the use of latex particles, which standardize the same fluorescent location on a daily basis. These can be used to adjust detector voltages and to determine the resolution and instrument sensitivity (1x Rainbow beads, 8x Rainbow beads and unstained COMP beads). Ultimately, these particles are linked to actual fluorochromes (e.g. FITC, PE, APC, Cy5PE, etc.) used in the instrument either on cells or on capture particles (e.g. COMP beads).

back to top

Photo of Mario Roederer, Ph.D.

Contact Info

Mario Roederer, Ph.D., Director
Phone: 301-594-8491
Fax: 301-480-2788
E-mail: Roederer@nih.gov

Stephen Perfetto, Manager
Phone:301-594-8659
Fax: 301-480-2788
E-mail:Sperfetto@nih.gov

Richard Nguyen, Specialist
E-mail: rnguyen@nih.gov

David Ambrozak, Specialist
E-mail:dambrozak@nih.gov

Mail:
NIH
Vaccine Research Center
40 Convent Drive
Bldg. 40, Room 5508
Bethesda, MD, 20892-3015


See Also

 Vaccine Research Center

 VRC Research Areas


NIH Logo

The National Institute of Allergy and Infectious Diseases is a component of the National Institutes of Health, U.S. Department of Health and Human Services

NIAID Logo

Search in Labs at NIAID
 
Print Icon Print this page
E-mail Icon E-mail this page
Plug-ins and Viewers
To open PDFs on this page, download and install the Adobe Acrobat Reader.
Photo of Mario Roederer, Ph.D.

Contact Info

Mario Roederer, Ph.D., Director
Phone: 301-594-8491
Fax: 301-480-2788
E-mail: Roederer@nih.gov

Stephen Perfetto, Manager
Phone:301-594-8659
Fax: 301-480-2788
E-mail:Sperfetto@nih.gov

Richard Nguyen, Specialist
E-mail: rnguyen@nih.gov

David Ambrozak, Specialist
E-mail:dambrozak@nih.gov

Mail:
NIH
Vaccine Research Center
40 Convent Drive
Bldg. 40, Room 5508
Bethesda, MD, 20892-3015


See Also

 Vaccine Research Center

 VRC Research Areas