The Flow Cytometry Section has several instruments available for use by researchers to facilitate flow cytometric analyses and sorting.

Instrument Specifications

Instrument Configuration and Capabilities Location
FACS Vantage SE-Blue
  • Two lasers: argon, argon-dye
  • Multi-parameter analysis and sterile sorting based on up to eight parameters (FS, SS, and six colors)
  • Turbo-Sort for high-speed sorting
  • OmniComp for interlaser compensation (i.e., PE-Cy5 and APC, PE and TR or PE-TR and TR)
Bldg. 4 Rm. B1-34
FACS Vantage SE-Orange
  • Two lasers: argon and HeNe
  • Multi-parameter analysis and sterile sorting based on up to eight parameters (FS, SS, and six colors)
  • Turbo-Sort for high-speed sorting
  • Digital Electronics (DiVa option) allowing all detector compensation and 4-way sorting
Bldg 4 Rm. B1-34
FACS Aria-Red
  • 3 lasers: 488nm, 405nm and 633nm solid state
  • Multi-parameter analysis and sterile sorting based on up to 15 parameters (FS, SS, 13 colors)
  • All Digital acquisition allowing all parameter compensation and four- way sorting
  • Single cell cloning into 96 or 24 well plates high-speed sorting (70 psi)
Bldg. 4 Rm. B1-34
BD LSR II
  • User-operated benchtop flow cytometer, 12 parameters (10 fluorescent colors and 2 light scatters)
  • 4 lasers: 488nm argon, 633nm HeNe, 407nm solid state, and 325nm HeCad with fixed alignment
  • Dyes capable of measuring: 488 laser dyes: FITC, PE, PE-Cy5, PE-Cy7, 325 laser dyes: Indo-1, Hoechst, DAPI 633 nm laser dyes: APC or Cy5 and APC-Cy7, 407nm laser dyes: Cascade Blue, Cascade Yellow, Alexa 430, CFP
  • User changeable filters, Quartz cuvette flow cell, Pulse processing on all parameters, All color compensation; DiVa digital acquisition software on Win2K PC
Bldg. 4 Rm. B1-34
FACScan
  • One laser: argon
  • Standard five-parameter analysis/double discrimination for DNA analysis
  • Macintosh platform (CellQuest) for data acquisition and analysis
Bldg. 50 Rm. 5430
FACS Calibur
  • Two lasers: argon, red diode (633nm)
  • Six parameter analysis and sorting/doublet discrimination for DNA analysis
  • Four-color analysis using FITC, PE, PE-Cy5 (or PerCP), and APC
  • Macintosh platform (CellQuest) for data acquisition and analysis
Bldg. 50 Rm. 5430
Luminex 100
  • Capable of measuring up to 100 different analytes/tube.
  • Technology: molecular reactions take place on the surface of microspheres.
  • Thousands of molecules are attached to the surface of internally color-coded microspheres.
  • Assigned color-code identifies the reaction throughout the test
  • Magnitude of the biomolecular reaction is measured using a second molecule called a reporter.
  • Reporter molecule signals the extent of the reaction by attaching to the molecules on the microspheres.
  • Two sources of color: the color-code inside the microsphere and the reporter color on the surface of the microsphere.
Bldg. 4 Rm. B1-34
FACS Aria-Green
  • Three lasers: 488nm, 405nm and 633nm solid state
  • Multi-parameter analysis and sterile sorting based on up to 12 parameters (FS, SS, 10 colors)
  • All Digital acquisition allowing all parameter compensation and four-way sorting
  • Single cell cloning into 96 or 24 well plates high-speed sorting (70 psi)
Twinbrook II Rm. 103C
FACS Calibur
  • Two lasers: argon, red diode (633nm)
  • Six-parameter analysis and sorting/doublet discrimination for DNA analysis
  • Four-color analysis using FITC, PE, PE-Cy5 (or PerCP), and APC
  • Macintosh platform (CellQuest) for data acquisition and analysis
Twinbrook II Rm. 103C